Web
Analytics

Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System

  Rofiatul Izah (1*), Subiyanto Subiyanto (2), Dhidik Prastiyanto (3)

(1) UNIVERSITAS NEGERI SEMARANG - Indonesia - [ https://www.researchgate.net/profile/Rofiatul_Izah ] orcid
(2) UNIVERSITAS NEGERI SEMARANG - Indonesia - [ https://www.researchgate.net/profile/Subiyanto_Subiyanto3 ] orcid
(3) UNIVERSITAS NEGERI SEMARANG - Indonesia orcid
(*) Corresponding Author

Received: January 09, 2018; Revised: February 28, 2018
Accepted: April 12, 2018; Published: August 31, 2018


How to cite (IEEE): R. Izah, S. Subiyanto,  and D. Prastiyanto, "Improvement of DSOGI PLL Synchronization Algorithm with Filter on Three-Phase Grid-connected Photovoltaic System," Jurnal Elektronika dan Telekomunikasi, vol. 18, no. 1, pp. 35-45, Aug. 2018. doi: 10.14203/jet.v18.35-45

Abstract

Synchronous Reference Frame Phase Locked Loop (SRF PLL) has been widely used for synchronization three-phase grid-connected photovoltaic (PV) system. On the grid fault, SRF PLL distorted by negative sequence component and grid harmonic that caused an error in estimating parameter because of ripple and oscillation. This work combined SRF PLL with Dual Second Order Generalized Integrator (DSOGI) and filter to minimize ripple and minimize oscillation in the phase estimation and frequency estimation. DSOGI was used for filtering and obtaining the 90o shifted versions from the vαβ signals. These signals (vαβ) were generated from three phase grid voltage signal using Clarke transform. The vαβ signal was the inputs to the positive-sequence calculator (PSC). The positive-sequence vαβ was transformed to the dq synchronous reference frame and became an input to SRF-PLL to create the estimation frequency. This estimation frequency from SRF PLL was filtered by the low-pass filter to decrease grid harmonic. Moreover, the output of low-pass filter was a frequency adaptive. The performance of DSOGI PLL with filter is compared with DSOGI PLL, SRF PLL, and IEEE standard 1547(TM)-2003. The improvement of DSOGI PLL with filter gave better performances than DSOGI PLL and SRF PLLbecause it minimized ripples and oscillations in the phase and frequency estimations.


  http://dx.doi.org/10.14203/jet.v18.35-45

Keywords


synchronization; DSOGI PLL; PSIM; photovoltaic system; grid connected

Full Text:

  PDF

References


World Energy Council, “World Energy Resources 2016,” inWorld Energy Resources 2016, 2016, pp. 1–33.

J. Khoury, R. Mbayed, G. Salloum, E. Monmasson, and J. Guerrero, “Review on the integration of photovoltaic renewable energy in developing countries - Special attention to the Lebanese case,” Renew. Sustain. Energy Rev., vol. 57, pp. 562–575, May 2016. Crossref

IEA PVPS, “Annual Report 2013,” 2013.

Z. Abdmouleh, A. Gastli, L. Ben-Brahim, M. Haouari, and N. A. Al-Emadi, “Review of optimization techniques applied for the integration of distributed generation from renewable energy sources,” Renewable Energy, vol. 113, pp. 266–280, Dec. 2017. Crossref

D. Boroyevich, I. Cvetkovic, R. Burgos, and D. Dong, “Intergrid: A future electronics energy network?,” IEEE Journal of Emerging Seected. Topics in Power Electronics, vol. 1, no. 6, pp. 127–136, Sep. 2013. Crossref

K. Arulkumar, K. Palanisamy, and D. Vijayakumar, “Recent Advances and Control Techniques in Grid Connected Pv System – A Review, ” International Journal of Renewable Energy Research, vol. 6, no. 3, pp. 1031-1049, 2016.

H. Calleja and H. Jimenez, “Performance of a grid connected PV system used as active filter,” Energy Conversion and Management, vol. 45, no. 15–16, pp. 2417–2428, Sep. 2004. Crossref

X. Tang, K. M. Tsang, and W. L. Chan, “Power conditioning system for grid-connected photovoltaic system,” Solar Energy, vol. 96, pp. 187–193, Oct. 2013. Crossref

S. L. Prakash, A. S. Jesudaiyan, and M. Arutchelvi, “Dynamic Simulation of Grid Tied PV-Inverter Under Distorted Grid Voltage,” International Journal Of Innovative Research In Electrical, Electronics, Instrumentation And Control Engineering, vol. 2, no. 9, pp. 1926–1932, 2014.

S. Natesan and J. Venkatesan, “A SRF-PLL control scheme for DVR to achieve grid synchronization and PQ issues mitigation in PV fed grid connected system,” Circuits and Systems, vol. 07, no. 10, pp. 2996–3015, 2016. Crossref

P. Kanjiya, B. Singh, A. Chandra, and K. A. Haddad, "“SRF Theory Revisited” to Control Self Supported Dynamic Voltage Restorer (DVR) for Unbalanced and Nonlinear loads," IEEE Transactions on Industry Applications, vol. 49, issue 5, pp. 1-9, 2013. Crossref

F. Blaabjerg, R. Teodorescu, M. Liserre, and A. V. Timbus, “Overview of control and grid synchronization for distributed power generation systems,” IEEE Trans. on Industrial Electronics, vol. 53, no. 5, pp. 1398–1409, Oct. 2006. Crossref

A. Nicastri and A. Nagliero, “Comparison and evaluation of the PLL techniques for the design of the grid-connected inverter systems,” in Proc. IEEE International Symposiumon Industrial Electronics, 2010, pp. 3865–3870. Crossref

M. Ciobotaru, R. Teodorescu, and F. Blaabjerg, “A new single-phase PLL structure based on second order generalized integrator,” in Proc. IEEE Power Electronics Specialist Conference, 2006. Crossref

A. Luna, C. Citro, C. Gavriluta, and J. Hermoso, “Advanced PLL structures for grid synchronization in distributed generation,” Renewable Energy and Power Quality Journal, pp. 1747–1756, Apr. 2012. Crossref

I. Setiawan, M. Facta, A. Priyadi, and M. H. Purnomo, “Comparison of three popular PLL schemes under balanced and unbalanced grid voltage conditions,” in Proc. 2016 8th International Conference on Information Technology and Electrical Engineering, 2016, pp. 6–11. Crossref

V. Kaura and V. Blasko, “Operation of a phase locked loop system under distorted utility conditions,” IEEE Trans. on Industry Applications, vol. 33, no. 1, pp. 58–63, 1997. Crossref

R. Urhekar and S. U. Kulkarni, “Study and simulation of SOGI PLL for single phase grid connected system,”International Journal of scientific Research in Science, Engginering and Technology, vol. 2, no. 2, pp. 741–745, 2016.

H. E. P. de Souza, F. Bradaschia, F. A. S. Neves, M. C. Cavalcanti, G. M. S. Azevedo, and J. P. de Arruda, “A method for extracting the fundamental-frequency positive-sequence voltage vector based on simple mathematical transformations,” IEEE Trans. Ind. Electron., vol. 56, no. 5, pp. 1539–1547, May 2009. Crossref

A. Kulkarni and V. John, “A novel design method for SOGI-PLL for minimum settling time and low unit vector distortion,” in Proc. IECON Industrial Electronics Conference, 2013, pp. 274–279. Crossref

S. Golestan, M. Monfard, F. D. Freijedo, and J. M. Guerrero, “Design and tuning of modified power based PLL for single phase grid connected power conditioning system,” IEEE Trans. on Power Electronics, vol. 27, no. 8, pp. 3639–3650, Aug. 2012. Crossref

IEEE Std 1547a-2014 - IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems Amendment 1, 2014.

F. Spertino and G. Graditi, “Power conditioning units in grid-connected photovoltaic systems: a comparison with different technologies and wide range of power ratings,” Solar Energy, vol. 108, pp. 219–229, Oct. 2014. Crossref

B. Singh, D. T. Shahani and A. K. Verma, "Power balance theory based control of grid interfaced solar photovoltaic power generating system with improved power quality," 2012 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), Bengaluru, 2012, pp. 1-7. Crossref

A. B. Rey-Bou, R. Garciaa-Valverde, F. D. A. Ruz-Vila, and J. M. Torrelo-Ponce, “An integrative approach to the design methodology for 3-phase power conditioners in Photovoltaic Grid-Connected systems,” Energy Conversion and Management, vol. 56, pp. 80–95, Apr. 2012. Crossref

H. Dammah, I. Lachkar, and S. L. Elhaq, “MPPT and PFC achievement in grid connected photovoltaic system based on a half bridge inverter,” in Proc. International Conference on Control Engineering & Information Technology, 2016, pp. 16–18. Crossref

A. Haque, “Maximum Power Point Tracking ( MPPT ) scheme for solar photovoltaic system,” Energy Technoly & Policy, vol. 1, no. 1, pp. 115–122, Jan. 2014. Crossref

L. Gao, R. A. Dougal, S. Liu, and A. P. Iotova, “Parallel-connected solar PV system to address partial and rapidly fluctuating shadow conditions,” IEEE Trans. on Industrial Electronics, vol. 56, no. 5, pp. 1548–1556, May 2009. Crossref

A. Gupta, “Three Phase Inverter Simulation using Sinusoidal PWM Technique,” International Journal of Advanced Researce in Electrical, Electronics and Instrumentation Engginering, vol. 6, issue 5, pp. 4102–4108, May 2017.

S. Kharjule, “Voltage source inverter,” in Proc. International Conference Energy Systems and Applications, 2015.

S. R. Bowes and D. Holliday, “Comparison of pulse-width-modulation control strategies for three-phase inverter systems,” in IEE Proc. Electric Power Applications, 2006. Crossref

N. Mutoh, M. Ohno, and T. Inoue, “A method for MPPT control while searching for parameters corresponding to weather conditions for PV generation systems,” IEEE Trans. Industrial Electronics, vol. 53, no. 4, pp. 1055–1065, June 2006. Crossref

S. K. Chung, “A phase tracking system for three phase utility interface inverters,” IEEE Trans. Power Electronics, vol. 15, no. 3, pp. 431–438, May 2000. Crossref

N. F. Guerrero-Rodríguez, A. B. Rey-Boué, L. C. Herrero-de Lucas, and F. Martinez-Rodrigo, “Control and synchronization algorithms for a grid-connected photovoltaic system under harmonic distortions, frequency variations and unbalances,” Renewable Energy, vol. 80, pp. 380–395, Aug. 2015. Crossref

P. Rodríguez, R. Teodorescu, I. Candela, A. V. Timbus, M. Liserre, and F. Blaabjerg, “New positive-sequence voltage detector for grid synchronization of power converters under faulty grid conditions,” in Proc. ofPESC - IEEE Power Electronics Specialist Conference, 2006. Crossref

Y. Han, M. Luo, X. Zhao, J. M. Guerrero, and L. Xu, “Comparative performance evaluation of orthogonal-signal-generators-based single-phase PLL algorithms - A Survey,” IEEE Trans. on Power Electronics, vol. 31, no. 5, pp. 3932–3944, May 2016. Crossref

M. Ciobotaru, R. Teodorescu, and V. G. Agelidis, “Offset rejection for PLL based synchronization in grid-connected converters,” in Proc. IEEE Applied Power Electronics Conference and Exposition - APEC, 2008, no. 1, pp. 1611–1617. Crossref

Park, Inverse Park And Clarke, Inverse Clarke Software, Transformations MSS Implementation, Microsemi, 2013.

A. Elsebaay, M. Ramadan, M. A. A. Adma, “Studying the Effect of Non-Linear Loads Harmonics on Electric Generator Power Rating Selection, ” European Scientific Journal, vol. 13, no. 18, pp. 1857-7881, July 2017. Crossref

A. P. Singhal, Defferance Between Linear Loads and Non-Linear Loads, Tricolite website.[Online] Available: http://www.tricolite.com/pdf/sources-eEffects-harmonics.pdf

N. Kuyvenhoven, “PID Tuning Methods An Automatic PID Tuning Study with MathCad,”Calvin College ENGR. 315, Dec. 2002.


Article Metrics

Metrics Loading ...

Metrics powered by PLOS ALM

Refbacks





Copyright (c) 2018 National Research and Innovation Agency

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.